作者
Divya A Chari, Alan D Workman, Jenny X Chen, David H Jung, Dunia Abdul-Aziz, Elliott D Kozin, Aaron K Remenschneider, Daniel J Lee, D Bradley Welling, Benjamin S Bleier, Alicia M Quesnel
发表日期
2021/1
期刊
Otolaryngology–Head and Neck Surgery
卷号
164
期号
1
页码范围
67-73
出版商
SAGE Publications
简介
Objective
To investigate small-particle aerosolization from mastoidectomy relevant to potential viral transmission and to test source-control mitigation strategies.
Study Design
Cadaveric simulation.
Setting
Surgical simulation laboratory.
Methods
An optical particle size spectrometer was used to quantify 1- to 10-µm aerosols 30 cm from mastoid cortex drilling. Two barrier drapes were evaluated: OtoTent1, a drape sheet affixed to the microscope; OtoTent2, a custom-structured drape that enclosed the surgical field with specialized ports.
Results
Mastoid drilling without a barrier drape, with or without an aerosol-scavenging second suction, generated large amounts of 1- to 10-µm particulate. Drilling under OtoTent1 generated a high density of particles when compared with baseline environmental levels (P < .001, U = 107). By contrast, when drilling was conducted under OtoTent2, mean particle density remained at baseline …
引用总数
20202021202220232024617941