作者
Rong‐Qin Zheng, Ren Mao, Jie Ren, Er‐Jiao Xu, Mei Liao, Ping Wang, Min‐Qiang Lu, Yang Yang, Chang‐Jie Cai, Gui‐Hua Chen
发表日期
2010/6
期刊
Liver Transplantation
卷号
16
期号
6
页码范围
729-735
出版商
Wiley Subscription Services, Inc., A Wiley Company
简介
Hepatic artery stenosis (HAS) is a common complication in liver transplant patients. Conventional angiography remains the gold standard for diagnosis. Recently, contrast‐enhanced ultrasound (CEUS) has begun providing real‐time angiographic‐like images of vessels and allowing the accurate diagnosis of arterial diseases such as hepatic artery thrombosis. The purpose of this study was to evaluate the efficacy of CEUS in depicting HAS after liver transplantation. Forty‐seven liver transplant recipients underwent CEUS examinations with the intravenous injection of microbubble contrast agents. The reference standard was conventional angiography for 15 patients and computed tomographic angiography for 32 patients. The presence, degree, location, and type of HAS were evaluated. For the detection of HAS by CEUS, the following was found: an accuracy of 91.5% (43/47), a sensitivity of 92.3% (36/39), a …
引用总数
2010201120122013201420152016201720182019202020212022202320241159511836646121