作者
Wei Deng, James E Younkin, Kevin Souris, Sheng Huang, Kurt Augustine, Mirek Fatyga, Xiaoning Ding, Marie Cohilis, Martin Bues, Jie Shan, Joshua Stoker, Liyong Lin, Jiajian Shen, Wei Liu
发表日期
2020/6
期刊
Medical physics
卷号
47
期号
6
页码范围
2558-2574
简介
Purpose
To commission an open source Monte Carlo (MC) dose engine, “MCsquare” for a synchrotron‐based proton machine, integrate it into our in‐house C++‐based I/O user interface and our web‐based software platform, expand its functionalities, and improve calculation efficiency for intensity‐modulated proton therapy (IMPT).
Methods
We commissioned MCsquare using a double Gaussian beam model based on in‐air lateral profiles, integrated depth dose of 97 beam energies, and measurements of various spread‐out Bragg peaks (SOBPs). Then we integrated MCsquare into our C++‐based dose calculation code and web‐based second check platform “DOSeCHECK.” We validated the commissioned MCsquare based on 12 different patient geometries and compared the dose calculation with a well‐benchmarked GPU‐accelerated MC (gMC) dose engine. We further improved the MCsquare efficiency by …
引用总数
2020202120222023202421017814