作者
Liyong Lin, Minglei Kang, Sheng Huang, Rulon Mayer, Andrew Thomas, Timothy D Solberg, James E McDonough, Charles B Simone
发表日期
2015/11
期刊
Journal of applied clinical medical physics
卷号
16
期号
6
页码范围
281-292
简介
The purpose of this study is to determine whether organ sparing and target coverage can be simultaneously maintained for pencil beam scanning (PBS) proton therapy treatment of thoracic tumors in the presence of motion, stopping power uncertainties, and patient setup variations. Ten consecutive patients that were previously treated with proton therapy to 66.6/1.8 Gy (RBE) using double scattering (DS) were replanned with PBS. Minimum and maximum intensity images from 4D CT were used to introduce flexible smearing in the determination of the beam specific PTV (BSPTV). Datasets from eight 4D CT phases, using uncertainty in stopping power and uncertainty in patient setup in each direction, were used to create PBS plans for the evaluation of 10 patients. Plans were normalized to provide identical coverage between DS and PBS. The average lung V20, V5, and mean doses were reduced from 29.0%, 35.0 …
引用总数
201620172018201920202021202220232024811961361474