作者
Akshay Mohan, Arvind Sivakumar, Prasad Nalabothu
发表日期
2021/6/17
期刊
BDJ open
卷号
7
期号
1
页码范围
22
出版商
Nature Publishing Group UK
简介
Introduction
Lateral cephalometric analysis continues to be one of the gold standard diagnostic aids in orthodontics, with various software available to enhance this.
Aim
This study was done to evaluate the accuracy and reliability of linear and angular measurements obtained from OneCeph digital cephalometric tracing and manual tracings in lateral cephalometry.
Methodology
This is a cross-sectional study done on twenty pre-treatment lateral cephalometric radiographs of subjects who reported to the postgraduate orthodontic clinic for orthodontic treatment over one month. Cephalometric tracings were done using OneCeph digital software and manual tracing method to evaluate nine parameters of Steiner’s cephalometric analysis. An Independent T-sample test was done between the mean values of manual and OneCeph tracing. Intra operator reliability was evaluated by paired T-test after a week.
Results
No …
引用总数