作者
Keith A Wear
发表日期
2001/7
期刊
IEEE transactions on ultrasonics, ferroelectrics, and frequency control
卷号
48
期号
4
页码范围
1079-1083
出版商
IEEE
简介
Frequency-dependent phase velocity (dispersion) has previously been measured in trabecular bone by several groups. In contrast to most biologic tissues, phase velocity in trabecular bone tends to decrease with frequency. A stratified model, consisting of alternating layers of bone and marrow (in vivo) or water (in vitro), has been employed in an attempt to explain this phenomenon. Frequency-dependent phase velocity was measured from 300 to 700 kHz in: 1) phantoms consisting of regularly spaced thin parallel layers of polystyrene sheets in water; and 2) 30 calcaneus samples in vitro. For the polystyrene phantoms, the agreement between theory and experiment was good. For the calcaneus samples, the model has some limited usefulness (uncertainty of about 5%) in predicting average phase velocity. More importantly, the model seems to perform consistently well for predicting the frequency dependence of …
引用总数
20022003200420052006200720082009201020112012201320142015201620172018201920202021202212257613748624111541
学术搜索中的文章