Evaluation of
Barrett PM, Komatireddy R, Haaser S et al. Comparison of 24-hour Holter monitoring with 14-day novel adhesive patch electrocardiographic monitoring. Am. J. Med. 127(1), 95.e11–95.e17 (2014). The investigation of cardiac arrhythmias in the outpatient ambulatory setting has traditionally been initiated with the Holter monitor. Using the continuous recording over 24 or 48 h, the Holter monitor permits the detection of baseline rhythm, dysrhythmia and conduction abnormalities, including heart block and changes in the ST segment that may indicate myocardial ischemia. However, apart from the bulkiness and inconvenience of the device itself, the lack of extended monitoring results in a diagnostic yield of typically less than 20%. In this study by Barrett et al., 146 patients referred for the evaluation of cardiac arrhythmia were prospectively enrolled to wear both the 24-h Holter monitor …