Gal Rubinstein, Cathrine M Moeller, Dor Lotan, Sharon Slomovich, Andrea Fernandez-Valledor, Lauren S Ranard, Nicole E Leahy, Annamaria Ladanyi, Daniel Oren, Kevin J Clerkin, Jayant K Raikhelkar, Veli K Topkara, Justin A Fried, Torsten Vahl, Paolo C Colombo, Yuji Kaku, Koji Takeda, Yoshifumi Naka, Melana Yuzefpolskaya, Gabriel T Sayer, Nir Uriel
发表日期
2024/1/1
期刊
Journal of Cardiac Failure
卷号
30
期号
1
页码范围
95-99
出版商
Churchill Livingstone
简介
Background
Aortic regurgitation (AR) is a common complication following left ventricular assist device (LVAD) implantation. We evaluated the hemodynamic implications of AR in patients with HeartMate 3 (HM3) LVAD at baseline and in response to speed changes.
Methods and Results
Clinically stable outpatients supported by HM3 who underwent a routine hemodynamic ramp test were retrospectively enrolled in this analysis. Patients were stratified based on the presence of at least mild AR at baseline speed. Hemodynamic and echocardiographic parameters were compared between the AR and non-AR groups. Sixty-two patients were identified. At the baseline LVAD speed, 29 patients (47%) had AR, while 33 patients (53%) did not. Patients with AR were older and supported on HM3 for a longer duration. At baseline speed, all hemodynamic parameters were similar between the groups including central venous …