作者
Cecilia Goracci, Ornella Raffaelli, Francesca Monticelli, Beatrice Balleri, Egidio Bertelli, Marco Ferrari
发表日期
2005/5/1
期刊
Dental materials
卷号
21
期号
5
页码范围
437-444
出版商
Elsevier
简介
OBJECTIVES
Aim of the study was to measure the adhesion between two types of translucent prefabricated FRC posts (FRC Postec, Ivoclar-Vivadent, FRC; Light-Post, RTD, LP), and two types of flowable composites used as core materials (UnifilFlow, GC, UF; Tetric Flow, Ivoclar-Vivadent, TF), with or without the application of a silane (Monobond-S, Ivoclar-Vivadent, S) on the post surface.
METHODS
The experimental groups were: 1.1 FRC+UF; 1.2 FRC+S+UF; 1.3 FRC+TF; 1.4 FRC+S+TF: 2.1 LP+UF; 2.2 LP+S+UF; 2.3 LP+TF; 1.4 LP+S+TF. The bond strength at the interface between post and core was measured with the microtensile non-trimming technique. Thirty to thirty-five beam-shaped specimens per group were obtained from cylinders of core material, which had been built up around the post by progressively adding small increments of composite resin. Each specimen was loaded in tension until failure at …
引用总数
20062007200820092010201120122013201420152016201720182019202020212022202320241827342726443531292320717211719893