作者
Matthew D Haydock, Cornelis Kruger, Timothy Willcox, David A Haydock
发表日期
2014/3/1
期刊
The Journal of ExtraCorporeal Technology
卷号
46
期号
1
页码范围
77-83
出版商
American Society of ExtraCorporeal Technology
简介
The Auckland Hospital cardiothoracic unit recently removed Mannitol and Voluven from its Plasma-lyte-based cardiopulmonary bypass (CPB) priming fluid. Like with any change to practice, a comprehensive audit should be performed to identify positive or negative effects. The aim of this retrospective analysis was to investigate the effect of changing the CPB prime constituents on fluid balance and clinical outcome parameters. Clinical records were reviewed for 100 consecutive patients undergoing primary, isolated coronary artery bypass grafting (CABG), 50 patients before the prime change and 50 after. All data were collated into a central database for analysis. Mean arterial pressure while on bypass was higher in the new prime group (61.5 mmHg versus 57.5 mmHg, p = .002). There was no significant difference in hematocrit, hemoglobin, serum sodium, serum potassium, or creatinine postoperatively between …
引用总数
201520162017201820192020202120222023121113121