作者
Anthony V D’Amico, Judi Manola, Marian Loffredo, Lynn Lopes, Kristopher Nissen, Desmond A O’Farrell, Leah Gordon, Clare M Tempany, Robert A Cormack
发表日期
2001/12/1
期刊
International Journal of Radiation Oncology* Biology* Physics
卷号
51
期号
5
页码范围
1431-1436
出版商
Elsevier
简介
Purpose
A practical method to achieve prostate immobilization and daily target localization for external beam radiation treatment is described.
Methods and Materials
Ten patients who underwent prostate brachytherapy using permanent radioactive source placement were selected for study. To quantify prostate motion both with and without the presence of a specially designed inflatable intrarectal balloon, the computerized tomography–based coordinates of all intraprostatic radioactive sources were compared over 3 consecutive measurements at 1-min intervals.
Results
The placement and inflation of the intrarectal balloon were well tolerated by all patients. The mean (range) displacement of the prostate gland when the intrarectal balloon was present vs. absent was 1.3 (0–2.2) mm vs. 1.8 (0–9.1) mm (p = 0.03) at 2 min respectively. The maximum displacement in any direction (anterior–posterior, superior–inferior …
引用总数
20022003200420052006200720082009201020112012201320142015201620172018201920202021595121312106311141431321634
学术搜索中的文章
AV D'Amico, J Manola, M Loffredo, L Lopes, K Nissen… - International Journal of Radiation Oncology* Biology …, 2001