作者
WI Suleiman, MF McEntee, SJ Lewis, MA Rawashdeh, D Georgian-Smith, R Heard, K Tapia, PC Brennan
发表日期
2016/1/1
期刊
Clinical radiology
卷号
71
期号
1
页码范围
e35-e40
出版商
WB Saunders
简介
Aim
To compare readers' performance in detecting architectural distortion (AD) compared with other breast cancer types using digital mammography.
Materials and methods
Forty-one experienced breast screen readers (20 US and 21 Australian) were asked to read a single test set of 30 digitally acquired mammographic cases. Twenty cases had abnormal findings (10 with AD, 10 non-AD) and 10 cases were normal. Each reader was asked to locate and rate any abnormalities. Lesion and case-based performance was assessed. For each collection of readers (US; Australian; combined), jackknife free-response receiver operating characteristic (JAFROC), figure of merit (FOM), and inferred receiver operating characteristic (ROC), area under curve (Az) were calculated using JAFROC v.4.1 software. Readers' sensitivity, location sensitivity, JAFROC, FOM, ROC, Az scores were compared between cases groups using …
引用总数
201620172018201920202021202220232024245821411
学术搜索中的文章