Objective
Retrospective comparisons of selected patients undergoing off-pump versus conventional on-pump coronary artery bypass grafting have yielded inconsistent results and raised concerns about completeness of revascularization in off-pump coronary artery bypass grafting.
Methods
Two hundred unselected patients referred for elective primary coronary artery bypass grafting were randomly assigned to undergo off-pump coronary artery bypass grafting with an Octopus tissue stabilizer (Medtronic, Inc, Minneapolis, Minn) or conventional coronary artery bypass grafting with cardiopulmonary bypass by a single surgeon. Revascularization intent determined before random assignment was compared with the revascularization performed. All management followed strict, unbiased, criteria-driven protocols. Patients and nonoperative care providers were blinded to surgical group.
Results
Baseline characteristics …
引用总数
20022003200420052006200720082009201020112012201320142015201620172018201920202021202220232024286670724947514750464029212419151613201674