Purpose
C-arm linac-based radiotherapy has seen a recent interest in 4π methods of delivery using simultaneous rotations of couch and gantry to reduce doses to organs-at-risk (OARs) and increase dose compactness. While many methods use heuristics to generate trajectories that avoid OARs, combined with arbitrary trajectory restrictions to prevent oversampling, a quantity has not yet been developed to succinctly compare sampling of the 4π space for candidate trajectories as a surrogate for dosimetric compactness.
Methods
Evenly spaced sampling points were distributed across a 4π sphere centred on isocentre. A metric, mean arc distance (MAD), was defined that quantifies the average arc distance between all sampling points and their nearest field in a radiotherapy trajectory. The relationship between isodose volume and MAD was examined in 2,047 plans: 900 unique trajectories of fixed port DCA plans …