作者
Koray Kilic, Gonca Erbas, Melike Guryildirim, Oznur Leman Konus, Mehmet Arac, Erhan Ilgit, Sedat Isik
发表日期
2013/5/1
期刊
Journal of computer assisted tomography
卷号
37
期号
3
页码范围
377-381
出版商
LWW
简介
Objectives
Our aim was to assess the effect of adaptive statistical iterative reconstruction (ASIR) on pediatric head computed tomography (CT) examinations.
Methods
We retrospectively reviewed 305 pediatric head CT examinations. The study population consisted of standard dose (STD, n= 152) examinations reconstructed with filtered back projection and low dose (LD, n= 153) examinations reconstructed with 30%(LD 30) and 0%(LD 0) ASIR. We compared groups by means of radiation dose, noise measures, and visual grading. Student t test, 1-way analysis of variance test, and Mann-Whitney U test were used for statistical analysis.
Results
The dose in the LD 30 group was significantly lower (29%) than that in the STD group (P< 0.001). The noise in the white matter (P< 0.001), SNR (P< 0.001), and subjective image noise (P= 0.044) was significantly better in the STD group than those in the LD 30 group. There was …