作者
Filippo Pesapane, Francesca Patella, Enrico Maria Fumarola, Silvia Panella, Anna Maria Ierardi, Giovanni Guido Pompili, Giuseppe Franceschelli, Salvatore Alessio Angileri, Alberto Magenta Biasina, Gianpaolo Carrafiello
发表日期
2017/3
期刊
Medical Oncology
卷号
34
页码范围
1-9
出版商
Springer US
简介
The aim of this study was to compare the Intravoxel Incoherent Motion (IVIM) parameters between healthy Peripheral Zone (PZ), Benign Prostatic Hyperplasia (BPH) and Prostate Cancer (PCa) and compare them to assess whether there was correlation with Gleason Score (GS) grading system. Thirty-one patients with suspect of PCa underwent 1.5T Multi-Parametric Magnetic Resonance Imaging (MP-MRI) with endorectal coil with a protocol including T2WI, DWI using 10 b values (0, 10, 20, 30, 50, 80, 100, 200, 400, 1000 s/mm2) and DCE. Monoexponential and IVIM model fits were used to calculate both apparent diffusion coefficient (ADC) and the following IVIM parameters: molecular diffusion coefficient (D), perfusion-related diffusion coefficient (D*) and perfusion fraction (f). The ADC and D values were significantly lower in the PCa (0.70 ± 0.16 × 10−3 mm2/s and 0.88 ± 0.31 × 10−3 mm2/s) compared to …
引用总数
20172018201920202021202220232024112812111052