作者
Sunil Shah, Mohammad Laiquzzaman, Sanjay Mantry, Ian Cunliffe
发表日期
2008/8
期刊
Clinical & experimental ophthalmology
卷号
36
期号
6
页码范围
508-513
出版商
Blackwell Publishing Asia
简介
Abstract
Purpose:  The aim of this study is to compare the hysteresis and corneal resistance factor (CRF) in normal tension glaucoma (NTG), primary open angle glaucoma (POAG) and ocular hypertension (OHT) eyes measured by the ocular response analyser (ORA).
Methods:  This is a prospective, cross‐sectional and comparative clinical trial. The setting was a teaching hospital in Birmingham, England. Patients: 216 eyes with POAG, 68 eyes with NTG and 199 eyes with OHT. Observational procedures: Goldmann applanation tonometry and intraocular pressure (IOP), hysteresis and CRF measured by ORA and central corneal thickness (CCT) by ultrasonic pachymetery. The main outcome measures were IOP, CCT, hysteresis and CRF.
Results:  The hysteresis in NTG, POAG and OHT eyes was 9.0 ± 1.9, 9.9 ± 2.1 and 10.2 ± 2.0 mmHg; CRF was 9.1 ± 2.2, 10.6 ± 2.0 and 12.0 ± 2.0 mmHg; IOP …
引用总数
200820092010201120122013201420152016201720182019202020212022202320241411712812111583647631