作者
Khawaja Taimoor Tanweer, Syed Rafay Hasan, Awais Mehmood Kamboh
发表日期
2017/5/28
研讨会论文
2017 IEEE international symposium on circuits and systems (ISCAS)
页码范围
1-4
出版商
IEEE
简介
Photoplethysomographic (PPG) signal is crucial for non-invasive monitoring of heart rate. It is acquired by using pulse oximeter that are prone to artifacts. A major application of this technique is monitoring the heart rate during physical exertion. Extraction of heart rate (HR) from the PPG in this case is difficult due to the strong motion related artifacts. This paper proposes an efficient method based on a reference generation using singular value decomposition and then multistage application of filtered X-LMS for removing motion artifacts from PPG signal. Simultaneous three-axis acceleration data is acquired and used as reference signal to measure time and extent of motion artifact in PPG signal. This is followed by an application of Slope Sum Method (SSM) to track peaks, and thus determine the heart rate. Testing of proposed method on PPG signals acquired from multiple subjects performing intense exercises …
引用总数
20182019202020212022202320242547886
学术搜索中的文章
KT Tanweer, SR Hasan, AM Kamboh - 2017 IEEE international symposium on circuits and …, 2017