作者
Adrian L Kelly, T Gough, Mohammad Isreb, R Dhumal, JW Jones, S Nicholson, AB Dennis, A Paradkar
发表日期
2018/4/3
期刊
Drug development and industrial pharmacy
卷号
44
期号
4
页码范围
670-676
出版商
Taylor & Francis
简介
Real time measurement of melt rheology has been investigated as a Process Analytical Technology (PAT) to monitor hot melt extrusion of an Active Pharmaceutical Ingredient (API) in a polymer matrix. A developmental API was melt mixed with a commercial copolymer using a heated twin screw extruder at different API loadings and set temperatures. The extruder was equipped with an instrumented rheological slit die which incorporated three pressure transducers flush mounted to the die surface. Pressure drop measurements within the die at a range of extrusion throughputs were used to calculate rheological parameters, such as shear viscosity and exit pressure, related to shear and elastic melt flow properties, respectively. Results showed that the melt exhibited shear thinning behavior whereby viscosity decreased with increasing flow rate. Increase in drug loading and set extrusion temperature resulted in a …
引用总数
20182019202020212022202320241417511
学术搜索中的文章
AL Kelly, T Gough, M Isreb, R Dhumal, JW Jones… - Drug development and industrial pharmacy, 2018