作者
Chenxi Sun, Jian Chen, Huamin Zhang, Xi Han, Qingtao Luo
发表日期
2010/2/1
期刊
Journal of Power Sources
卷号
195
期号
3
页码范围
890-897
出版商
Elsevier
简介
Diffusion coefficients of the vanadium ions across Nafion 115 (Dupont) in a vanadium redox flow battery (VRFB) are measured and found to be in the order of V2+>VO2+>VO2+>V3+. It is found that both in self-discharge process and charge–discharge cycles, the concentration difference of vanadium ions between the positive electrolyte (+ve) and negative electrolyte (−ve) is the main reason causing the transfer of vanadium ions across the membrane. In self-discharge process, the transfer of water includes the transfer of vanadium ions with the bound water and the corresponding transfer of protons with the dragged water to balance the charges, and the transfer of water driven by osmosis. In this case, about 75% of the net transfer of water is caused by osmosis. In charge–discharge cycles, except those as mentioned in the case of self-discharge, the transfer of protons with the dragged water across the membrane …
引用总数
201120122013201420152016201720182019202020212022202320241626212531335137495051344730