简介
Background
Rotational knee stability provided by the anterior cruciate ligament (ACL) in the pivot-shift phenomena involves analysis of more complex robotic testing profiles and resulting tibiofemoral compartment kinematics and subluxations.
Hypotheses
Using anterior-posterior tibial forces along with internal and valgus tibial moments will produce a major anterior subluxation of both tibiofemoral compartments not obtained with internal and valgus moments alone. Increasing the internal torque in pivot-shift testing will constrain the anterior subluxations of the medial and central tibial compartments.
Study Design
Controlled laboratory study.
Methods
A 6 degrees of freedom robotic knee testing system applied anterior translation and rotational loading profiles in 10 cadaveric knees before and after ACL sectioning. Changes in knee motion limits were measured, and medial and lateral tibiofemoral compartment …