Purpose
To compare the vessel calibre measurements between optical coherence tomography angiography (OCTA) and colour fundus photography.
Methods
In this retrospective comparative study, OCTA and colour fundus images of healthy eyes and eyes with optic atrophy were evaluated. The colour fundus image was registered manually using Image J software to the OCTA image of the optic disc. Two independent graders measured the vessel calibre of the widest vein and artery in each peripapillary quadrant on a 3.4 mm diameter circle centred on the optic disc in the same location on both images. The difference in vessel calibre between the two techniques was assessed.
Results
A total of 312 vessels from 29 healthy eyes and 20 eyes with atrophic optic discs were included. There was a high level of agreement between graders for measurement of vessel calibre in both colour fundus (intraclass correlation …