Christian Labadie, Jing‐Huei Lee, William D Rooney, Silvia Jarchow, Monique Aubert‐Frécon, Charles S Springer Jr, Harald E Möller
发表日期
2014/1
期刊
Magnetic resonance in medicine
卷号
71
期号
1
页码范围
375-387
简介
Purpose
Magnetic resonance T1‐weighted images are routinely used for human brain segmentation, brain parcellation, and clinical diagnosis of demyelinating diseases. Myelin is thought to influence the longitudinal relaxation commonly described by a mono‐exponential recovery, although reports of bi‐exponential longitudinal relaxation have been published. The purpose of this work was to investigate if a myelin water T1 contribution could be separated in geometrically sampled Look‐Locker trains of low flip angle gradient echoes.
Methods
T1 relaxograms from normal human brain were computed by a spatially regularized inverse Laplace transform after estimating the apparent inversion efficiency.
Results
With sufficiently long inversion‐time sampling (ca. 5 × T1 of cerebrospinal fluid), the T1 relaxogram revealed a short‐T1 peak (106–225 ms). The apparent fraction of this water component increased in …