作者
David UJ Keller, Frank M Weber, Gunnar Seemann, Olaf Dössel
发表日期
2010/6/14
期刊
IEEE Transactions on Biomedical Engineering
卷号
57
期号
7
页码范围
1568-1576
出版商
IEEE
简介
This paper examined the effects that different tissue conductivities had on forward-calculated ECGs. To this end, we ranked the influence of tissues by performing repetitive forward calculations while varying the respective tissue conductivity. The torso model included all major anatomical structures like blood, lungs, fat, anisotropic skeletal muscle, intestine, liver, kidneys, bone, cartilage, and spleen. Cardiac electrical sources were derived from realistic atrial and ventricular simulations. The conductivity rankings were based on one of two methods: First, we considered fixed percental conductivity changes to probe the sensitivity of the ECG regarding conductivity alterations. Second, we set conductivities to the reported minimum and maximum values to evaluate the effects of the existing conductivity uncertainties. The amplitudes of both atrial and ventricular ECGs were most sensitive for blood, skeletal muscle …
引用总数
20102011201220132014201520162017201820192020202120222023202431351041115141812713956
学术搜索中的文章
DUJ Keller, FM Weber, G Seemann, O Dössel - IEEE Transactions on Biomedical Engineering, 2010