作者
P Cattarello, SDH Soedirdjo, B Afsharipour, R Merletti
发表日期
2017
研讨会论文
Converging Clinical and Engineering Research on Neurorehabilitation II: Proceedings of the 3rd International Conference on NeuroRehabilitation (ICNR2016), October 18-21, 2016, Segovia, Spain
页码范围
1013-1017
出版商
Springer International Publishing
简介
The purpose of this work is to evaluate the effect of the electrode size on recorded High Density surface electromyography (HDsEMG) maps. We recorded the sEMG signals using a grid of electrodes (16 × 8) placed on biceps brachii (5 mm inter electrode distance, IED). Each instantaneous map was interpolated using the 2D Sinc function to obtain a “continuous” map (CM, with 10,000 samp/m). To simulate acquisition with different electrode sizes, each CM was filtered with a circular averaging filter (2–10 mm diameter) and re-sampled with 10 mm IED. Inverse transfer function to compensate the effect of electrode size was applied on each map. The results suggest that greater electrode size implies higher error of power (RMS2) of each map values with respect to the CM. The error of power estimation introduced by electrode size is smaller than the error due to IED.
引用总数
20192020202120222231
学术搜索中的文章
P Cattarello, SDH Soedirdjo, B Afsharipour, R Merletti - Converging Clinical and Engineering Research on …, 2017