作者
Zhonghua Sun, Robert Davidson, Cheng HSun Lin
发表日期
2009/3/1
来源
European journal of radiology
卷号
69
期号
3
页码范围
489-495
出版商
Elsevier
简介
PURPOSE
The aim of this study was to perform a systematic review of the diagnostic accuracy of multi-detector row computed tomography angiography (MDCT) for detection of coronary in-stent restenosis in patients treated with coronary stenting when compared to invasive catheter angiography.
MATERIALS AND METHODS
A search of PUBMED and MEDLINE databases for English literature was performed. Only studies with at least 10 patients comparing 16- or more detector rows MDCT angiography with invasive catheter angiography in the detection of coronary in-stent restenosis (more than 50% stenosis) were included for analysis. Sensitivity and specificity estimates pooled across studies were tested using a fixed effects model.
RESULTS
15 studies met selection criteria for inclusion in the analysis. There were eight studies performed with 16-detector row CT scanners, and five studies with 64-detector row …
引用总数
200820092010201120122013201420152016201720182019202020212022202328710146101244323414