作者
Tita Oktavia Cahya Rahayu, Ni Luh Wulan Septiani, Gilang Gumilar, Damar Rastri Adhika, Brian Yuliarto
发表日期
2021/6/28
期刊
IEEE Sensors Journal
卷号
21
期号
18
页码范围
19959-19966
出版商
IEEE
简介
In this study, magnetite (Fe 3 O 4 ) was composited with graphene (Gr) and used as a non-enzymatic glucose sensor material based of surface plasmon resonance (SPR). The Fe 3 O 4 nanoparticles were succesfully synthesized by ultrasonic co-precipitation method while variation composition of composite samples was successfully prepared at room temperature by varying the concentration ratio of graphene and Fe 3 O 4 . The resulting composites have good crystallinity and purity with Fe 3 O 4 nanoparticles attach on the graphene surface. The commercial gold (Au) chip with a thickness of 50 nm was modified with a composite by depositing the various compositions of the composite on the Au chip surface using a spin coater. The most optimal SPR response was shown by the Fe 3 O 4 -Gr (3:1) sample with a shift in resonance intensity of 18.2 r.u in detecting 5 mM of glucose. Moreover, the detection limit of the …
引用总数