Objectives
In this retrospective study, we examined the incidence of post-procedural conduction abnormalities and the need for pacing in patients undergoing percutaneous implantation of the aortic valve.
Background
Safety and feasibility studies have suggested anecdotally the occurrence of conduction abnormalities and requirements for pacing after percutaneous implantation of the aortic valve.
Methods
We examined the standard 12-lead electrocardiograms (ECGs) of 40 consecutive patients in whom a CoreValve Revalving System (CoreValve, Paris, France) was implanted between November 2005 and March 2008. We examined the 12-lead ECG before treatment, after treatment, and at 1-month follow-up. We documented the requirements for temporary or permanent pacemaking.
Results
The mean age of patients was 82 ± 7 years. Post-procedural mortality at 72 h was 0%. There was a significant increase in the …