作者
Ebony B Carter, Cheryl S Chu, Zach Thompson, Methodius G Tuuli, George A Macones, Alison G Cahill
发表日期
2020/3
期刊
American journal of perinatology
卷号
37
期号
04
页码范围
378-383
出版商
Thieme Medical Publishers
简介
Objective This study aimed to determine the association between nuchal cord, electronic fetal monitoring parameters, and adverse neonatal outcomes.
Study Design This was a prospective cohort study of 8,580 singleton pregnancies. Electronic fetal monitoring was interpreted, and patients with a nuchal cord at delivery were compared with those without. The primary outcome was a composite neonatal morbidity index. Logistic regression was used to adjust for confounders.
Result Of 8,580 patients, 2,071 (24.14%) had a nuchal cord. There was no difference in the risk of neonatal composite morbidity in patients with or without a nuchal cord (8.69 vs. 8.86%; p = 0.81). Nuchal cord was associated with category II fetal heart tracing and operative vaginal delivery (OVD) (6.4 vs. 4.3%; p < 0.01).
Conclusion Nuchal cord is associated with category II electronic fetal monitoring parameters, which may drive …
引用总数
201920202021202220232024132421