作者
AM1 Hövels, RAM Heesakkers, EM Adang, GJ Jager, S Strum, YL Hoogeveen, JL Severens, JO Barentsz
发表日期
2008/4/1
来源
Clinical radiology
卷号
63
期号
4
页码范围
387-395
出版商
WB Saunders
简介
AIM
To compare the diagnostic accuracy of computed tomography (CT) and magnetic resonance imaging (MRI) in the diagnosis of lymph node metastases in prostate cancer.
METHODS
After a comprehensive literature search, studies were included that allowed construction of contingency tables for detection of lymph node metastases using CT or MRI. In addition, a summary receiver-operating characteristic (ROC) analysis was performed.
RESULTS
A total of 24 studies were included. For CT, pooled sensitivity was 0.42 (0.26–0.56 95% CI) and pooled specificity was 0.82 (0.8–0.83 95% CI). For MRI, the pooled sensitivity was 0.39 (0.22–0.56 95% CI) and pooled specificity was 0.82 (0.79–0.83 95% CI). The differences in performance of CT and MRI were not statistically significant.
CONCLUSION
CT and MRI demonstrate an equally poor performance in the detection of lymph node metastases from prostate cancer …
引用总数
200820092010201120122013201420152016201720182019202020212022202320244111919394249628180110102115115948734