作者
Christelle Huet, Jonathan Eakins, Maria Zankl, José María Gómez-Ros, Jan Jansen, Montserrat Moraleda, Lara Struelens, Deepak K Akar, Jorge Borbinha, Hrvoje Brkić, Duc Ky Bui, Kevin Capello, Thi My Linh Dang, Laurent Desorgher, Salvatore Di Maria, Lior Epstein, Dario Faj, Karin Fantinova, Paolo Ferrari, Sebastian Gossio, John Hunt, Zoran Jovanovic, Han Sung Kim, Dragana Krstic, Ngoc Thiem Le, Yi-Kang Lee, Manohari Murugan, Minal Y Nadar, Ngoc-Quynh Nguyen, Dragoslav Nikezic, Hemant K Patni, Denison Souza Santos, Marilyn Tremblay, Sebastian Trivino, Katarzyna Tymińska
发表日期
2022/1/1
期刊
Radiation measurements
卷号
150
页码范围
106695
出版商
Pergamon
简介
This paper summarizes the results of an intercomparison on the use of the ICRP Reference Computational Phantoms with radiation transport codes, which was organized by EURADOS working group 6. Three exercises are described: exposure to an anterior-posterior (AP) photon point source, exposure to an AP neutron point source, and exposure to two typical medical X-ray examinations. The three exercises received 17, 8 and 8 solutions, respectively. Participants originated from fifteen different countries, and used a wide range of Monte Carlo codes. Due to difficulties in defining the precise source location unambiguously in the exercise description, agreement to within ∼10% of the reference solution was considered satisfactory for a given participant's results. Although some participants provided initial solutions in good agreement with the reference solutions, differences of several tens of percent, or even …
引用总数