作者
S Busoni, M Bruzzi, S Giomi, C Poggiali, M Quattrocchi, M Betti, D D'Urso, L Fedeli, LN Mazzoni, M Paolucci, F Rossi, A Taddeucci, S Bettarini, P Tortoli, G Belli, L Bernardi, C Gasperi, F Campanella
发表日期
2022/12/1
期刊
Physica Medica
卷号
104
页码范围
123-128
出版商
Elsevier
简介
Purpose
This study investigated the radiation dose to surgeon eye lens for single procedure and normalised to exposure parameters for eight selected neuroradiology, cardiovascular and radiology interventional procedures.
Methods
The procedures investigated were diagnostic study, Arteriovenous Malformations treatment (AVM) and aneurysm embolization for neuroradiology procedures, Coronary Angiography and Percutaneous Transluminal Coronary Angioplasty (CA-PTCA), Pacemaker and Implantable Cardioverter-Defibrillator implantation (PM-ICD), Endovascular Aortic Repair (EVAR) and Fenestrated Endovascular Aortic Repair (FEVAR) for cardiovascular and electrophysiology procedures. CT-guided lung biopsy was also monitored.
All procedures were performed with table-mounted and ceiling-suspended shields (0.5 mm lead equivalent thickness), except for FEVAR and PM-ICD where only a table …