作者
Andrew T Schilling, Jeff Ehresman, Zach Pennington, Ethan Cottrill, James Feghali, A Karim Ahmed, Andrew Hersh, Ryan F Planchard, Yike Jin, Daniel Lubelski, Majid Khan, Kristin J Redmond, Timothy Witham, Sheng-fu Larry Lo, Daniel M Sciubba
发表日期
2021/10/1
期刊
World neurosurgery
卷号
154
页码范围
e277-e282
出版商
Elsevier
简介
Background
Vertebral bone quality had a significant impact on postoperative outcomes in spinal fusion surgery. New magnetic resonance imaging−based measures, such as the Vertebral Bone Quality (VBQ) score, may allow for bone quality assessment without the radiation associated with conventional testing. In the present study, we sought to assess the intrarater and interrater reliability of VBQ scores calculated by medical professionals and trainees.
Methods
Thirteen reviewers of various specialties and levels of training were recruited and asked to calculate VBQ scores for 30 patients at 2 time points separated by 2 months. Scored volumes were acquired from patients treated for both degenerative and oncologic indications. Intrarater and interrater agreement, quantified by intraclass correlation coefficient (ICC), was assessed using 2-way random effects modeling. Square-weight Cohen κ and Kendall Tau-b were …
引用总数
学术搜索中的文章
AT Schilling, J Ehresman, Z Pennington, E Cottrill… - World neurosurgery, 2021