Computer-aided subtraction of the co-registered and normalized interictal from the ictal single photon emission tomography (SPET) scan, followed by co-registration to the magnetic resonance image, may improve the utility of ictal SPET in the localization of partial epilepsy. This paper describes and technically validates our method. The SPET to SPET co-registration was tested using six sequential 99 Tc m brain phantom SPET images of different known positions (15 matches). The registration error was determined by multiplying the calculated match transformation matrix by the inverse of the known transformation matrix. The ‘worst case’co-registration error was less that one voxel diameter in all cases (median 3.2 mm, range 1.2–4.8 mm). For interictal to ictal SPET registrations in 10 consecutive intractable partial epilepsy patients, a similar root mean square distance (RMSD) between corresponding points on the …
引用总数
1998199920002001200220032004200520062007200820092010201120122013201420152016201720182019202020212022202320244811131061891181795585851026429322