作者
Franziska A Schmidt, Hervé M Lekuya, Sertac Kirnaz, Robert Nick Hernandez, Ibrahim Hussain, Louis Chang, Rodrigo Navarro-Ramirez, Christoph Wipplinger, Cameron Rawanduzy, Roger Härtl
发表日期
2022/7
期刊
Global Spine Journal
卷号
12
期号
6
页码范围
1098-1108
出版商
SAGE Publications
简介
Study Design
Prospective case series.
Objective
SSPSS (single step pedicle screw system) was developed for minimally invasive spine surgery. We performed this study to report on safety, workflow, and our initial clinical experience with this novel technique.
Methods
The prospective study was conducted on patients who underwent pedicle screw fixation between October 2017 and April 2018 using a novel single step 3D navigated pedicle screw system for MIS. Outcome measurements were obtained from intraoperative computerized tomography. The images were evaluated to determine pedicle wall penetration. We used a grading system to assess the severity of the pedicle wall penetration. Breaches were classified as grade 1 (<2 mm), grade 2 (2-4 mm), or grade 3 (<4 mm), and as cranial, caudal, medial, and lateral.
Results
Our study includes 135 screws in 24 patients. SSPSS eliminated K-wires and multiple …
引用总数
20212022202320242622