作者
Gerald E Hanks, Timothy E Schultheiss, Alexandra L Hanlon, Margie Hunt, W Robert Lee, Barry E Epstein, Lawrence R Coia
发表日期
1997/2/1
期刊
International Journal of Radiation Oncology* Biology* Physics
卷号
37
期号
3
页码范围
543-550
出版商
Elsevier
简介
Purpose
The development of conformal radiation technique including improved patient immobilization has allowed us to test the value of dose escalation in optimizing the radiation treatment of prostate cancer.
Methods and Materials
Outcome is reported for 233 consecutive patients treated with conformal technique between March 1989 and October 1992. Dose was escalated from 68 Gy to 79 Gy. Patient status is reported at 3 years follow-up, which is available in all alive patients. Pretreatment and serial posttreatment prostate specific antigen (PSA) values are available for all patients. Pretreatment and serial post >1.5 ngm/ml and rising on two consecutive measures. Dose response for bNED control of cancer and late morbidity are represented by logit response models fitted to the data. Kaplan-Meier methods, the log rank test, and Cox Regression models are also used.
Results
No dose response is observed for …
引用总数
199719981999200020012002200320042005200620072008200920102011201220132014201520162017201820192020202120225202032122019191314983453345111
学术搜索中的文章
GE Hanks, TE Schultheiss, AL Hanlon, M Hunt… - International Journal of Radiation Oncology* Biology …, 1997