作者
Young Kyung Lim, Jungwon Kwak, Dong Wook Kim, Dongho Shin, Myonggeun Yoon, Soah Park, Jin Sung Kim, Sung Hwan Ahn, Jungwook Shin, Se Byeong Lee, Sung Yong Park, Hong Ryeol Pyo, Dae Yong Kim, Kwan Ho Cho
发表日期
2009/8/1
期刊
International Journal of Radiation Oncology* Biology* Physics
卷号
74
期号
5
页码范围
1609-1616
出版商
Elsevier
简介
PURPOSE
We examined the feasibility of using fiducial markers composed of microscopic gold particles and human-compatible polymers as a means to overcome current problems with conventional macroscopic gold fiducial markers, such as dose reduction and artifact generation, in proton therapy for prostate cancer.
METHODS AND MATERIALS
We examined two types of gold particle fiducial marker interactions: that with diagnostic X-rays and with a therapeutic proton beam. That is, we qualitatively and quantitatively compared the radiographic visibility of conventional gold and gold particle fiducial markers and the CT artifacts and dose reduction associated with their use.
RESULTS
The gold particle fiducials could be easily distinguished from high-density structures, such as the pelvic bone, in diagnostic X-rays but were nearly transparent to a proton beam. The proton dose distribution was distorted <5% by the …
引用总数
201020112012201320142015201620172018201920202021202220232251332432352
学术搜索中的文章
YK Lim, J Kwak, DW Kim, D Shin, M Yoon, S Park… - International Journal of Radiation Oncology* Biology …, 2009