作者
Paolo Ferrari, S Fidler, J Wright, C Woodroffe, P Slater, A Van Althuis-Jones, R Holdsworth, FT Christiansen
发表日期
2011/2/1
期刊
American Journal of Transplantation
卷号
11
期号
2
页码范围
272-278
出版商
Elsevier
简介
We developed and tested a new computer program to match maximal sets of incompatible live donor/recipient pairs from a national paired kidney donation (PKD) registry. Data of 32 incompatible pairs included ABO and 4 digit-high-resolution donor and recipient HLA antigens and recipient’s HLA antibodies. Three test runs were compared, in which donors were excluded from matching to recipients with either donor-specific antibodies (DSA) >8000MFI (mean fluorescent intensity) at low-resolution (Run 1) or >8000MFI at high-resolution (Run 2) or >2000MFI and high-resolution (Run 3). Run 1 identified 22 703 possible combinations, with 20 pairs in the top ranked, Run 2 identified 24 113 combinations, with 19 pairs in the top ranked and Run 3 identified 8843 combinations, with 17 pairs in the top ranked. Review of DSA in Run 1 revealed that six recipients had DSA 2000–8000MFI causing a possible positive …
引用总数
20112012201320142015201620172018201920202021202236101342444411
学术搜索中的文章
P Ferrari, S Fidler, J Wright, C Woodroffe, P Slater… - American Journal of Transplantation, 2011