作者
Daniela Bassi, Aldair Darlan Santos-de-Araújo, Patrícia Faria Camargo, Almir Vieira Dibai-Filho, Moyrane Abreu da Fonseca, Renata Gonçalves Mendes, Audrey Borghi-Silva
发表日期
2018/12
期刊
Journal of Medical Systems
卷号
42
页码范围
1-7
出版商
Springer US
简介
Heart rate variability (HRV) among other methods can be used to assess diabetic cardiac autonomic neuropathy by cardiac intervals were recorded. However, the amount of error depending on this measurement methodology is unclear. To evaluate the intra- and inter-rater reliability to calculate HRV indices, comparing different times and by different trained examiners in patients with type 2 diabetes mellitus (T2DM). Thirty individuals of both genders, aged between 18 and 45 years, with T2DM. The RR interval (RRi) were recorded during a 10 min period on supine position using a portable heart rate monitor (Polar® S810i model). HRV indices were calculated by the software Kubios® HRV analysis (version 2.2). Linear (Mean RRi; STD RR; Mean HR; rMSSD; RR Tri; TINN LF; HF; total power) and non-linear (SD1; SD2; DFα1; DFα2, ApEn and, SampEn) indices were calculated by two examiners with an interval of …
引用总数
20192020202120222023202412911141