作者
PJ O'Brien, DEC Smith, TJ Knechtel, MA Marchak, I Pruimboom-Brees, DJ Brees, DP Spratt, FJ Archer, P Butler, AN Potter, JP Provost, J Richard, PA Snyder, WJ Reagan
发表日期
2006/4/1
期刊
Laboratory Animals
卷号
40
期号
2
页码范围
153-171
出版商
SAGE Publications
简介
This study directly demonstrates that cardiac troponin I (cTnI) is a sensitive, specific, and persistent biomarker in laboratory animals. Histopathological and pathophysiological cardiac changes in dogs, rats and mice correlated with increased serum cTnI with various cardiac inotropic agents, and cardiotoxic drugs and with cardiac arrhythmias, tachycardia, cardiac effusion with dyspnoea, and ageing. A comparison of six immunoassays for cTnI and cardiac troponin T (cTnT) to detect and monitor cardiac injury in a rodent model indicated that enzyme-linked immunosorbent (Life Diagnostics Inc and TriChem Resources Inc, West Chester, Philadelphia, USA) and Immulite (Diagnostic Products Corporation, Llanberis, UK) assays had low sensitivity and less than 1% of the dynamic range of Centaur (Bayer Healthcare Diagnostics, Newbury, UK) cTnI and Elecsys (Roche Diagnostics, Basel, Switzerland) and M8 (Bioveris …
引用总数
2006200720082009201020112012201320142015201620172018201920202021202220232024310181825262026273128302122141220135