作者
Adil Ahmed, Srinivasan Vairavan, Abbasali Akhoundi, Gregory Wilson, Caitlyn Chiofolo, Nicolas Chbat, Rodrigo Cartin-Ceba, Guangxi Li, Kianoush Kashani
发表日期
2015/10/1
期刊
Journal of critical care
卷号
30
期号
5
页码范围
988-993
出版商
WB Saunders
简介
Introduction
Timely detection of acute kidney injury (AKI) facilitates prevention of its progress and potentially therapeutic interventions. The study objective is to develop and validate an electronic surveillance tool (AKI sniffer) to detect AKI in 2 independent retrospective cohorts of intensive care unit (ICU) patients. The primary aim is to compare the sensitivity, specificity, and positive and negative predictive values of AKI sniffer performance against a reference standard.
Methods
This study is conducted in the ICUs of a tertiary care center. The derivation cohort study subjects were Olmsted County, MN, residents admitted to all Mayo Clinic ICUs from July 1, 2010, through December 31, 2010, and the validation cohort study subjects were all patients admitted to a Mayo Clinic, Rochester, campus medical/surgical ICU on January 12, 2010, through March 23, 2010. All included records were reviewed by 2 independent …
引用总数
2015201620172018201920202021202220232024211681110111112