作者
Scott L Parker, Matthew J McGirt, S Harrison Farber, Anubhav G Amin, Anne-Marie Rick, Ian Suk, Ali Bydon, Daniel M Sciubba, Jean-Paul Wolinsky, Ziya L Gokaslan, Timothy F Witham
发表日期
2011/1/1
期刊
Neurosurgery
卷号
68
期号
1
页码范围
170-178
出版商
LWW
简介
BACKGROUND:
Pedicle screws are used to stabilize all 3 columns of the spine, but can be technically demanding to place. Although intraoperative fluoroscopy and stereotactic-guided techniques slightly increase placement accuracy, they are also associated with increased radiation exposure to patient and surgeon as well as increased operative time.
OBJECTIVE:
To describe and critically evaluate our 7-year institutional experience with placement of pedicle screws in the thoracic and lumbar spine using a free-hand technique.
METHODS:
We retrospectively reviewed records of all patients undergoing free-hand pedicle screw placement without fluoroscopy in the thoracic or lumbar spine between June 2002 and June 2009. Incidence and extent of cortical breach by misplaced pedicle screw was determined by review of postoperative computed tomography scans. We defined breach as more than 25% of the screw …
引用总数
201120122013201420152016201720182019202020212022202320247812332121242224363129299