This paper presents a comparative assessment of the cost and quality of treatment of tannery wastewater in India by two common effluent treatment plants (CETPs) constructed for two tannery clusters, at Jajmau (Kanpur) and at Unnao in the state of Uttar Pradesh, India. The Jajmau plant is upflow anaerobic sludge blanket (UASB) process-based, while the Unnao plant is activated sludge process (ASP)-based. Investigations indicated that the ASP-based plant was superior in all respects. Total annualized costs, including capital and operation and maintenance costs, for the UASB and ASP plants were Rs. 4.24 million/million liters per day (MLD) and Rs. 3.36 million/MLD, respectively. Land requirements for the two CETPs were 1.4 hectares/MLD and 0.95 hectares/MLD, respectively. Moreover, the treated UASB effluent had higher biochemical and chemical oxygen demand (BOD/COD) and considerable …