Sung Joong Choo, Jinsik Kim, Kyung Woon Lee, Dong Ho Lee, Hyun-Joon Shin, Jung Ho Park
发表日期
2014/7/1
期刊
Current Applied Physics
卷号
14
期号
7
页码范围
954-959
出版商
North-Holland
简介
We report the design and fabrication of an integrated Mach–Zehnder interferometric (MZI) biochip based on silicon oxynitride layers deposited with a plasma-enhanced chemical vapor deposition (PECVD) process. A rib waveguide for an integrated MZI sensor has been designed to have a high surface sensitivity and a single-mode behavior by using an effective index method. The integrated MZI chip operating at 637 nm is fabricated via conventional photolithography and reactive ion etching. As a biosensor application, the real-time and label-free detection of the covalent immobilization and hybridization of DNA strands is performed and verified with this device.