简介
Background and Purpose
Outcome measurement fidelity within and between sites of multi-site, randomized, clinical trials is an essential element to meaningful trial outcomes. As important are the methods developed for randomized, clinical trials that can have practical utility for clinical practice. A standardized measurement method and rater training program were developed for the total Fugl-Meyer motor and sensory assessments; inter-rater reliability was used to test program effectiveness.
Methods
Fifteen individuals with hemiparetic stroke, 17 trained physical therapists across 5 regional clinical sites, and an expert rater participated in an inter-rater reliability study of the Fugl-Meyer motor (total, upper extremity, and lower extremity subscores) and sensory (total, light touch, and proprioception subscores) assessments.
Results
Intra-rater reliability for the expert rater was high for the motor and sensory scores (range, 0 …
学术搜索中的文章
KJ Sullivan, JK Tilson, SY Cen, DK Rose, J Hershberg… - Stroke, 2011