BACKGROUND
Epidural analgesia is widely used for pain relief during labor. The purpose of this study was to determine if ultrasound measurement of the depth from skin to epidural space before the epidural technique decreases the failure rate of labor analgesia. A secondary objective was to correlate ultrasound depth to the epidural space with actual depth of the needle at placement.
METHODS
In this prospective, randomized, non-blinded study, 370 parturients requesting labor epidural analgesia were randomized to receive their epidural technique by first year anesthesia residents with or without prior ultrasound determination of epidural space depth. Outcome variables included the incidence of epidural catheter replacement for failed analgesia and the number of epidural attempts and accidental dural punctures.
RESULTS
The ultrasound group had fewer epidural catheter replacements (P<0.02), and …