作者
Cuie Duan, Weizhen Lu, Yunwei Zhang, Zhaolin Gu
发表日期
2018/3
期刊
Indoor and Built Environment
卷号
27
期号
3
页码范围
402-422
出版商
SAGE Publications
简介
This paper concerns urban canopies populated with tall slender buildings. To clarify the controlling factors of urban canopies, we simulated a series of single high-rise buildings under fully developed turbulence at a realistic scale by large-eddy simulation. We then analysed correlations between the drag force and recirculation area, frontal area, surface area, floor area, porosity and inlet velocity. Our results show that the recirculation length and recirculation area were proportional to the width, height and wind speed, but were inversely proportional to the length of a building. New equations for the recirculation length and area are presented. The maximum error of the recirculation length equation was 6.66%, and the maximum error of the recirculation area equation was 7.49%. The drag source characteristic length was found to be proportional to the recirculation area, frontal area and surface area and inversely …
引用总数
学术搜索中的文章