作者
Anna E Engberg, Per H Nilsson, Shan Huang, Karin Fromell, Osama A Hamad, Tom Eirik Mollnes, Jenny P Rosengren-Holmberg, Kerstin Sandholm, Yuji Teramura, Ian A Nicholls, Bo Nilsson, Kristina N Ekdahl
发表日期
2015/1/1
期刊
Biomaterials
卷号
36
页码范围
55-65
出版商
Elsevier
简介
Inappropriate complement activation is often responsible for incompatibility reactions that occur when biomaterials are used. Complement activation is therefore a criterion included in legislation regarding biomaterials testing. However, no consensus is yet available regarding appropriate complement-activation-related test parameters. We examined protein adsorption in plasma and complement activation/cytokine release in whole blood incubated with well-characterized polymers. Strong correlations were found between the ratio of C4 to its inhibitor C4BP and generation of 10 (mainly pro-inflammatory) cytokines, including IL-17, IFN-γ, and IL-6. The levels of complement activation products correlated weakly (C3a) or not at all (C5a, sC5b-9), confirming their poor predictive values. We have demonstrated a direct correlation between downstream biological effects and the proteins initially adhering to an artificial …