作者
Sung-Han Yoon, Tobias Schmidt, Sabine Bleiziffer, Niklas Schofer, Claudia Fiorina, Antonio J Munoz-Garcia, Ermela Yzeiraj, Ignacio J Amat-Santos, Didier Tchetche, Christian Jung, Buntaro Fujita, Antonio Mangieri, Marcus-Andre Deutsch, Timm Ubben, Florian Deuschl, Shingo Kuwata, Chiara De Biase, Timothy Williams, Abhijeet Dhoble, Won-Keun Kim, Enrico Ferrari, Marco Barbanti, E Mara Vollema, Antonio Miceli, Cristina Giannini, Guiherme F Attizzani, William KF Kong, Enrique Gutierrez-Ibanes, Victor Alfonso Jimenez Diaz, Harindra C Wijeysundera, Hidehiro Kaneko, Tarun Chakravarty, Moody Makar, Horst Sievert, Christian Hengstenberg, Bernard D Prendergast, Flavien Vincent, Mohamed Abdel-Wahab, Luis Nombela-Franco, Miriam Silaschi, Giuseppe Tarantini, Christian Butter, Stephan M Ensminger, David Hildick-Smith, Anna Sonia Petronio, Wei-Hsian Yin, Federico De Marco, Luca Testa, Nicolas M Van Mieghem, Brian K Whisenant, Karl-Heinz Kuck, Antonio Colombo, Saibal Kar, Cesar Moris, Victoria Delgado, Francesco Maisano, Fabian Nietlispach, Michael J Mack, Joachim Schofer, Ulrich Schaefer, Jeroen J Bax, Christian Frerker, Azeem Latib, Raj R Makkar
发表日期
2017/12/5
期刊
Journal of the American College of Cardiology
卷号
70
期号
22
页码范围
2752-2763
出版商
American College of Cardiology Foundation
简介
Background
Limited data exist about safety and efficacy of transcatheter aortic valve replacement (TAVR) in patients with pure native aortic regurgitation (AR).
Objectives
This study sought to compare the outcomes of TAVR with early- and new-generation devices in symptomatic patients with pure native AR.
Methods
From the pure native AR TAVR multicenter registry, procedural and clinical outcomes were assessed according to VARC-2 criteria and compared between early- and new-generation devices.
Results
A total of 331 patients with a mean STS score of 6.7 ± 6.7 underwent TAVR. The early- and new-generation devices were used in 119 patients (36.0%) and 212 patients (64.0%), respectively. STS score tended to be lower in the new-generation device group (6.2 ± 6.7 vs. 7.6 ± 6.7; p = 0.08), but transfemoral access was more frequently used in the early-generation device group (87.4% vs. 60.8%; p < 0.001 …