Purpose
To compare the accuracy of the SRK/T and Haigis formulas for predicting corneal astigmatism correction with a toric intraocular lens (IOL).
Setting
Department of Ophthalmology, Korea University College of Medicine, Seoul, South Korea.
Design
Retrospective cross-sectional study.
Methods
Eyes with an Acrysof toric IOL were enrolled in the study. The corneal plane effective cylinder power of toric IOLs (target induced astigmatism vector [TIA]) predicted by the SRK/T and Haigis formulas were compared with the cylindrical correction achieved postoperatively (surgically induced astigmatism vector [SIA]). The magnitude of error was defined as the difference between the magnitudes of the SIA and TIA. The median absolute magnitudes of error predicted by the SRK/T and Haigis formulas were compared. The median absolute errors predicted by the 2 formulas were also compared.
Results
The mean postoperative …
引用总数
2015201620172018201920202021202220232024147445111